Sku: PM80D-1
8″TFT-LCD display ,   Support Capacitive touch screen. Support various modules including 3/5/12 Leads ECG,RESP,SPO2, NIBP,IBP,CO2,AG etc. Support Multi display interface, e.g. LCD,VGA, HDMI, Miracast Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee Built-in...
8″TFT-LCD display ,   Support Capacitive touch screen. Support various modules including 3/5/12 Leads ECG,RESP,SPO2, NIBP,IBP,CO2,AG etc. Support Multi display interface, e.g. LCD,VGA, HDMI, Miracast Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee Built-in...
Sino-k
$390.00
Quantity:
+
-
  • Estimated delivery time 3-15 days

  • $5.00 off Discount Code: SINOKMED5OFF

  • Easy Returns: Hassle-free, 30 days Return Policy

  • Description

      • 8″TFT-LCD display ,   Support Capacitive touch screen.
      • Support various modules including 3/5/12 Leads ECG,RESP,SPO2,
      • NIBP,IBP,CO2,AG etc.
      • Support Multi display interface, e.g. LCD,VGA, HDMI, Miracast
      • Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee
      • Built-in detachable rechargeable lithium battery(about 6h)
      • Support multi-language,Central Monitoring system

      ECG                                                                    

      Lead selection: I, II, III, aVR, aVL, aVF, V
      Gain:x 0.25mm/mV, x 0.5mm/mV, x 1mm/mV, x 2mm/mV
      Measurement and alarm range: 15~300 bpm(Adult) 15~350 bpm(Neonatal)
      Resolution: 1 bpm
      Alarm accuracy: ± 1 %
      ST measurement and alarm range: -2.0 - +2.0mV
      Alarm accuracy: ± 10 %
      Pacemaker: yes
      Sweep speed: 12.5mm/s, 25 mm/s, 50 mm/s
      Bandwidth: Diagnostic: 0.05~130 Hz
      Monitor: 0.05~40Hz
      Surgery: 1~20 Hz

      NIBP                                                                   

      Work Mode: Manual, Automatic, Continuous
      Unit: mmHg, kPa
      Measurement and alarm range:
      Adult:  SYS: 40 ~ 280 mmHg
                 DIA: 10 ~ 225 mmHg
                 MEAN: 20 ~ 240 mmHg
      Pediatric: SYS: 40 ~ 220 mmHg
                      DIA: 10 ~ 160 mmHg
                      MEAN: 20 ~ 170 mmHg
      Neonatal: SYS: 40 ~ 135 mmHg
                      DIA: 10 ~ 100 mmHg
                      MEAN: 20 ~ 110 mmHg
      Resolution: 1 mmHg
      Accuracy: ±5 mmHg port upgrade via network

      RESP                                                                   

      Measurement and alarm range: 0~150 rpm
      Resolution: 1 Brpm
      Measurement accuracy: ±2 %

      SpO2                                                                    

       Measurement and alarm range: 0 ~ 100%
      Resolution: 1%
      Measurement accuracy: 70%~100%: ±2%;
      0%~69%: unspecified
      Measurement and alarm range: 20 ~ 250 bpm
      Resolution: 1 BPM
      Measurement accuracy: ±3 bpm

      TEMP                                                                    

      Measurement and alarm range: 0 ~ 50℃
      Resolution: 0.1 ℃
      Accuracy: ±0.1 ℃

      Packaging Included:

      1. Power Cable x 1 pc

      2. Ground Cable x 1 pc

      3. Power Adapter x 1 pc

      4. User Manual x 1 pc

      5. Patient Monitor PM80D x 1 pc

        • 8″TFT-LCD display ,   Support Capacitive touch screen.
        • Support various modules including 3/5/12 Leads ECG,RESP,SPO2,
        • NIBP,IBP,CO2,AG etc.
        • Support Multi display interface, e.g. LCD,VGA, HDMI, Miracast
        • Suport Multi-Communication interface, e.g. WiFi,Bluetooth,Zigbee
        • Built-in detachable rechargeable lithium battery(about 6h)
        • Support multi-language,Central Monitoring system

        ECG                                                                    

        Lead selection: I, II, III, aVR, aVL, aVF, V
        Gain:x 0.25mm/mV, x 0.5mm/mV, x 1mm/mV, x 2mm/mV
        Measurement and alarm range: 15~300 bpm(Adult) 15~350 bpm(Neonatal)
        Resolution: 1 bpm
        Alarm accuracy: ± 1 %
        ST measurement and alarm range: -2.0 - +2.0mV
        Alarm accuracy: ± 10 %
        Pacemaker: yes
        Sweep speed: 12.5mm/s, 25 mm/s, 50 mm/s
        Bandwidth: Diagnostic: 0.05~130 Hz
        Monitor: 0.05~40Hz
        Surgery: 1~20 Hz

        NIBP                                                                   

        Work Mode: Manual, Automatic, Continuous
        Unit: mmHg, kPa
        Measurement and alarm range:
        Adult:  SYS: 40 ~ 280 mmHg
                   DIA: 10 ~ 225 mmHg
                   MEAN: 20 ~ 240 mmHg
        Pediatric: SYS: 40 ~ 220 mmHg
                        DIA: 10 ~ 160 mmHg
                        MEAN: 20 ~ 170 mmHg
        Neonatal: SYS: 40 ~ 135 mmHg
                        DIA: 10 ~ 100 mmHg
                        MEAN: 20 ~ 110 mmHg
        Resolution: 1 mmHg
        Accuracy: ±5 mmHg port upgrade via network

        RESP                                                                   

        Measurement and alarm range: 0~150 rpm
        Resolution: 1 Brpm
        Measurement accuracy: ±2 %

        SpO2                                                                    

         Measurement and alarm range: 0 ~ 100%
        Resolution: 1%
        Measurement accuracy: 70%~100%: ±2%;
        0%~69%: unspecified
        Measurement and alarm range: 20 ~ 250 bpm
        Resolution: 1 BPM
        Measurement accuracy: ±3 bpm

        TEMP                                                                    

        Measurement and alarm range: 0 ~ 50℃
        Resolution: 0.1 ℃
        Accuracy: ±0.1 ℃

        Packaging Included:

        1. Power Cable x 1 pc

        2. Ground Cable x 1 pc

        3. Power Adapter x 1 pc

        4. User Manual x 1 pc

        5. Patient Monitor PM80D x 1 pc

        Just added to your wishlist:
        My Wishlist
        You've just added this product to the cart: