Sku: SNP9000N
Features &Benefits: 11” color TFT display, high resolution:800×600dpi; Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation...
Features &Benefits: 11” color TFT display, high resolution:800×600dpi; Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation...
Sino-k
$450.00
Quantity:
+
-
  • Estimated delivery time 3-15 days

  • $5.00 off Discount Code: SINOKMED5OFF

  • Easy Returns: Hassle-free, 30 days Return Policy

  • Description

    Features &Benefits:

    1. 11” color TFT display, high resolution:800×600dpi;
    2. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
    3. Real time S-T segment analysis,and ARR analysis;
    4. SpO2 Pitch Tone Variationand Drug Dose Calculation;
    5. Parameter waveform and characters color selectable
    6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
    7. Standby mode for Energy savingand suspend monitoring;
    8. 7-lead ECG waveforms display in phase;
    9. Capture dynamic waveforms;
    10. Built-in rechargeablelithium battery, and battery volume checking,
    11. AC power checking
    12. Efficient resistance to interference of defibrillator and HF knife;
    13. SINNOR F-6 SpO2 technology, VS NELLCORaccuracy;
    14. Networking capacity and TCP/IP networking platformenable abundant future upgrade
    15. Time delay switch-offfunction keep the monitor data restart monitor;
    16. Complete and flexible mounting solution for transportation and in-patient monitoring
    17. Can do with SpO2, ECG, NIBP, Temp, HR, PR, AG, IBP, EtCO2, N2O. with our Strong R &D team.
    18. SpO2 can work well In the condition of the low perfution of the patient
    19. Can work in ICU, OR, ER.
    20. Permanent suspensionof the Alarm with one button


    Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.

    Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,




    Performance Specifications

    Display:       12.1”color TFT

    Rolling and refreshing waveform display

    Resolution: 800×600

    Multi display selectable including:

    Large-font display

    Trend coexist display

    OxyCRG dynamic view display.

    Bed-to-bed view display

    Trace:             9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

    Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:          Power/battery indicator light

    QRS beep and alarm sound

    Battery:           Rechargeable lead acid cell, 12v/4AH

    Max.24 hour for charging, 4 hours for continue working

    Trend:             Parameter graphic and tabular trends:

    5s/piece,8 hours;

    1min/piece,168 hours(24hour×7days)

    5min/piece,1000 hours.


    Storage:           NIBP: 1000 groups

    Alarm: 200 groups

    Full disclosure waveforms: 3600S

    SD card external storage

    Alarm:         User-adjustable High, Medium and Low limits 3-level

     Audible and visual alarm

    Networking:        Connected to central monitoring system

    TCP/IP netting platform

    Recorder:         Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:    Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record


    Standard parameter:

    ECG:


    Lead mode: 5 –lead(R,L,F,N,C)

    Lead selection : I,II,III,avR,avL,avF,V

    Waveform:     3 and 7 channel selectable

    Gain selection: 0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s

    Heart rate range:    Adult: 15~300bpm;

    Neonate/pediatric:15~350bpm

    Accuracy: +1bpm or +1%,whichecer is greater

    Resolution:     1bpm

    Filter: surgery mode:1~20Hz

    monitor model:0.5~40Hz

    Diagnostic mode:0.05~130Hz

    Scaling signal: 1mv,+3%

    Protection:       withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

    Alarm range: 15~350bpm

    S-T segment detecton:

    Measurement range:  2.0mV~+2.0mV                         


     Alarm Range:         -2.0mV~ +2.0mV

    Accuracy:            -0.8mV ~+0.8Mv

    Error:               +0.02Mv

     

    Arrhythmia analysis: YES


    SPO2

    Measurement range:        0~100%

    Resolution:                1%

    Accuracy:                 +2%(70-100%);0-69% unspecified

    Alarm range               0~100%

    Pluse Rate:                

    range:        20~300bpm

    Resolution:   1bpm

    Error:        +1bpm or +2%,whichever is greater


    NIBP

    Method:                   Digital Automatic oscillometric

    Operation mode :            Manual/Automatic/continuous

    Auto measurement time:      Adjustable(1~480min)

    Measurement Unit:          mmHg/Kpa selectable

    Measurement types:         Systolic, Diastolic, Mean  

    Measurement tange:

    Range of Systolic pressure:    Adult: 40~270mmHg

    Pediatric: 40~220mmHg

    Neonate: 40~135mmHg

    Range of mean pressure:      Adult: 20~235mmHg

    Pediatric: 20~165mmHg

    Neonate: 20~110mmHg

    Range of diastolic pressure:   Adult: 10~215mmHg

    Pediatric: 10~150mmHg

    Neonate :10~100mmHg

    Over-pressure protection:     Double safety protection

    Resolution:                 1 mmHg

    Alarm:                    Systolic.Diastolic,Mean



    RESPIRATION

    Method:                     Thoracic impedance

    Measurement range:           Adult:7~120rpm;

    Neonate/Pediatric:7~150rpm

    Apnea alarm:                 YES,10~40s

    Resolution:                   1rpm

    Accuracy:                    +2rpm



    TEMPERATURE

    Compatible probe:             YSI or CYF

    Measurement range:           5~50℃

    Resolution :                   0.1℃

    Accuracy:                    +0.1℃

    Refreshing time:               about 1

    Average measuring time:        <10s



    Optional parameters:


    IBP

    Channel: 2 channels

    Range: -50-300mmHg

    Resolution: 1mmHg

    Accuracy: ±4mmHg(±4%)

    Unit: mmHg, Kpa

    Converter Sensitivity: 5mV/V/mmHg

    Transducer sites: ART/PA/CVP/LAP/RAP/ICP


    EtCO2( Sidertream CO2)

    Measurement range:   0~99mmHg

    Accuracy:   +2mmHg (0~40mmHg)

    Sampling Range:   100ml/min

    Sampling rate accuracy:   15%

    Respiration rate:   0~120rmp

    Respiration accuracy:  +2rmp (0~70rmp)

    +5rmp (>70rmp)

    Respiration time:   <240msec (10% to 90%)

    Delay time:  <2s

     

    EtCO2 (mainstreaam CO2)

    Method:   Infrared Spectrum

    Range:   0.0-10% (0~76%)

    Resolution:   1mmHg (0.1%)

    Accuracy:   <5%(±4.0 mmHg)

             Or<10%(of Readings)


    Recorder:     

    Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:  Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record




    Miscellaneous

     

    Satety:              

    Safety level: Class I, type CF


    Dimendion and Weight

    Dimendion:      28*42*48cm         

    G.Weight:        <6.5KS


    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:       working≤85%

    Transportation and storage≤93%

    Power:          AC 100-240,50/60Hz

    Patient range:    Neonate,pediatric,and adult patients


     

    Accessories supplies

    (1) 5 lead ECG cable  

    (2) 1 spo2 probes  

    (3) 1 NIBP prbe  

    (4) 1 temp probe

    (5)1 ground connecting liner  

    (6) Chest electrode (10pcs/set)

    Features &Benefits:

    1. 11” color TFT display, high resolution:800×600dpi;
    2. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
    3. Real time S-T segment analysis,and ARR analysis;
    4. SpO2 Pitch Tone Variationand Drug Dose Calculation;
    5. Parameter waveform and characters color selectable
    6. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
    7. Standby mode for Energy savingand suspend monitoring;
    8. 7-lead ECG waveforms display in phase;
    9. Capture dynamic waveforms;
    10. Built-in rechargeablelithium battery, and battery volume checking,
    11. AC power checking
    12. Efficient resistance to interference of defibrillator and HF knife;
    13. SINNOR F-6 SpO2 technology, VS NELLCORaccuracy;
    14. Networking capacity and TCP/IP networking platformenable abundant future upgrade
    15. Time delay switch-offfunction keep the monitor data restart monitor;
    16. Complete and flexible mounting solution for transportation and in-patient monitoring
    17. Can do with SpO2, ECG, NIBP, Temp, HR, PR, AG, IBP, EtCO2, N2O. with our Strong R &D team.
    18. SpO2 can work well In the condition of the low perfution of the patient
    19. Can work in ICU, OR, ER.
    20. Permanent suspensionof the Alarm with one button


    Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.

    Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,




    Performance Specifications

    Display:       12.1”color TFT

    Rolling and refreshing waveform display

    Resolution: 800×600

    Multi display selectable including:

    Large-font display

    Trend coexist display

    OxyCRG dynamic view display.

    Bed-to-bed view display

    Trace:             9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

    Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:          Power/battery indicator light

    QRS beep and alarm sound

    Battery:           Rechargeable lead acid cell, 12v/4AH

    Max.24 hour for charging, 4 hours for continue working

    Trend:             Parameter graphic and tabular trends:

    5s/piece,8 hours;

    1min/piece,168 hours(24hour×7days)

    5min/piece,1000 hours.


    Storage:           NIBP: 1000 groups

    Alarm: 200 groups

    Full disclosure waveforms: 3600S

    SD card external storage

    Alarm:         User-adjustable High, Medium and Low limits 3-level

     Audible and visual alarm

    Networking:        Connected to central monitoring system

    TCP/IP netting platform

    Recorder:         Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:    Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record


    Standard parameter:

    ECG:


    Lead mode: 5 –lead(R,L,F,N,C)

    Lead selection : I,II,III,avR,avL,avF,V

    Waveform:     3 and 7 channel selectable

    Gain selection: 0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s

    Heart rate range:    Adult: 15~300bpm;

    Neonate/pediatric:15~350bpm

    Accuracy: +1bpm or +1%,whichecer is greater

    Resolution:     1bpm

    Filter: surgery mode:1~20Hz

    monitor model:0.5~40Hz

    Diagnostic mode:0.05~130Hz

    Scaling signal: 1mv,+3%

    Protection:       withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

    Alarm range: 15~350bpm

    S-T segment detecton:

    Measurement range:  2.0mV~+2.0mV                         


     Alarm Range:         -2.0mV~ +2.0mV

    Accuracy:            -0.8mV ~+0.8Mv

    Error:               +0.02Mv

     

    Arrhythmia analysis: YES


    SPO2

    Measurement range:        0~100%

    Resolution:                1%

    Accuracy:                 +2%(70-100%);0-69% unspecified

    Alarm range               0~100%

    Pluse Rate:                

    range:        20~300bpm

    Resolution:   1bpm

    Error:        +1bpm or +2%,whichever is greater


    NIBP

    Method:                   Digital Automatic oscillometric

    Operation mode :            Manual/Automatic/continuous

    Auto measurement time:      Adjustable(1~480min)

    Measurement Unit:          mmHg/Kpa selectable

    Measurement types:         Systolic, Diastolic, Mean  

    Measurement tange:

    Range of Systolic pressure:    Adult: 40~270mmHg

    Pediatric: 40~220mmHg

    Neonate: 40~135mmHg

    Range of mean pressure:      Adult: 20~235mmHg

    Pediatric: 20~165mmHg

    Neonate: 20~110mmHg

    Range of diastolic pressure:   Adult: 10~215mmHg

    Pediatric: 10~150mmHg

    Neonate :10~100mmHg

    Over-pressure protection:     Double safety protection

    Resolution:                 1 mmHg

    Alarm:                    Systolic.Diastolic,Mean



    RESPIRATION

    Method:                     Thoracic impedance

    Measurement range:           Adult:7~120rpm;

    Neonate/Pediatric:7~150rpm

    Apnea alarm:                 YES,10~40s

    Resolution:                   1rpm

    Accuracy:                    +2rpm



    TEMPERATURE

    Compatible probe:             YSI or CYF

    Measurement range:           5~50℃

    Resolution :                   0.1℃

    Accuracy:                    +0.1℃

    Refreshing time:               about 1

    Average measuring time:        <10s



    Optional parameters:


    IBP

    Channel: 2 channels

    Range: -50-300mmHg

    Resolution: 1mmHg

    Accuracy: ±4mmHg(±4%)

    Unit: mmHg, Kpa

    Converter Sensitivity: 5mV/V/mmHg

    Transducer sites: ART/PA/CVP/LAP/RAP/ICP


    EtCO2( Sidertream CO2)

    Measurement range:   0~99mmHg

    Accuracy:   +2mmHg (0~40mmHg)

    Sampling Range:   100ml/min

    Sampling rate accuracy:   15%

    Respiration rate:   0~120rmp

    Respiration accuracy:  +2rmp (0~70rmp)

    +5rmp (>70rmp)

    Respiration time:   <240msec (10% to 90%)

    Delay time:  <2s

     

    EtCO2 (mainstreaam CO2)

    Method:   Infrared Spectrum

    Range:   0.0-10% (0~76%)

    Resolution:   1mmHg (0.1%)

    Accuracy:   <5%(±4.0 mmHg)

             Or<10%(of Readings)


    Recorder:     

    Build-in, thermal array

    Plethysmogram caveform:2 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:  Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record




    Miscellaneous

     

    Satety:              

    Safety level: Class I, type CF


    Dimendion and Weight

    Dimendion:      28*42*48cm         

    G.Weight:        <6.5KS


    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:       working≤85%

    Transportation and storage≤93%

    Power:          AC 100-240,50/60Hz

    Patient range:    Neonate,pediatric,and adult patients


     

    Accessories supplies

    (1) 5 lead ECG cable  

    (2) 1 spo2 probes  

    (3) 1 NIBP prbe  

    (4) 1 temp probe

    (5)1 ground connecting liner  

    (6) Chest electrode (10pcs/set)

    Just added to your wishlist:
    My Wishlist
    You've just added this product to the cart:
    Go to cart page